1   Scope

This document specifies guidance on how to conduct fit testing of tight-fitting respiratory protective device (RPD) and on appropriate methods to be used. Fit testing is only one element of a complete RPD programme. The intention of fit testing is to evaluate the effectiveness of the seal between the wearer’s face and the respiratory interface (RI). A complete RPD programme is defined in ISO/TS 16975‑1.
This document specifies requirements for conducting RPD fit testing and includes
  • qualifications/competences of fit-test operators,
  • specific fit-testing procedures,
  • interpretation of fit-test results, and
  • record keeping.
A fit test is not required for escape-only RPD.