Maintenance of electrical switchgear and controlgear for voltages above 1 kV and up to and including 36 kV. Code of practice

Maintenance of electrical switchgear and controlgear for voltages above 1 kV and up to and including 36 kV. Code of practice

Regular price
£260.00
Sale price
£260.00
Regular price
£130.00
Sold out
Unit price
per 

BS 6626:2010 Maintenance of electrical switchgear and controlgear for voltages above 1 kV and up to and including 36 kV. Code of practice

BS 6626 is a British Standard which gives recommendations and guidance for the maintenance of electrical switchgear and controlgear having a rated a.c. or d.c. voltage above 1 kV and up to and including 36 kV.

BS 6626 doesn’t apply to explosion protected switchgear and controlgear. See BS EN 60079-17.

BS 6626 covers applications above 1 kV. Voltages below 1 kV are considered to be low voltage in line with the European Commission Directive 73/23/EEC [1], known as the “Low voltage directive”.

Contents of BS 6626:

Foreword

Section 1: General

1 Scope

2 Normative references

3 Terms and definitions

4 Maintenance policy

5 Operational policy

6 Competence

Section 2: Safety

7 Personal protective equipment and treatment of persons suffering from electric shock

8 Operational experience

9 Safety rules and procedures for safe systems of work

10 Equipment location

11 Isolation and access for maintenance

12 Preparing for maintenance work

13 Fire extinguishing equipment

14 Testing

15 Disposal of scrap

Section 3: Common recommendations relating to maintenance

16 Manufacturer’s instructions

17 Newly commissioned equipment

18 Frequency of maintenance

19 Records and drawings

20 Replacement parts

21 Cleanliness

22 Marking of covers and connections

23 Quality of connections

24 Maintenance and testing of insulation

25 Maintenance of safety earthing continuity

26 Shutters, locking devices, etc.

27 Interlocks

28 Ventilation

29 Equipment heating and lighting

30 Lifting devices

31 Tripping and closing supplies

32 Equipment tools, spares and test instruments

33 Conclusion of maintenance

Section 4: Additional recommendations relating to the maintenance of specific items

34 Circuit breakers

35 Switches

36 Disconnectors and earthing switches

37 Busbars and busbar chambers

38 Fuses

39 Contactors

40 Overload protective devices

41 Relays

42 Timing devices

43 Protective, measuring and control transformers

44 Instruments including recorders

45 Capacitors

46 Power electronic equipment

47 Cable boxes and terminations

48 Control switches including pushbuttons and limit switches

49 Liquid starters, controllers and resistors

50 Manual controllers

51 Sealed switches

52 Actuators

53 Indicator devices

54 Batteries

55 Compressed air plant