Communication networks and systems for power utility automation - Guideline to exchanging information from a CDC-based data model using IEC 60870-5-101 or IEC 60870-5-104

Communication networks and systems for power utility automation - Guideline to exchanging information from a CDC-based data model using IEC 60870-5-101 or IEC 60870-5-104

Regular price
£336.00
Sale price
£336.00
Regular price
£168.00
Sold out
Unit price
per 

DD IEC/TS 61850-80-1:2009 Communication networks and systems for power utility automation. Guideline to exchanging information from a CDC-based data model using IEC 60870-5-101 or IEC 60870-5-104

DD IEC/TS 61850-80-1 is a technical specification which gives guidelines on how to exchange information from a CDC based data model (for example IEC 61850) using IEC 60870-5-101 or IEC 60870-5-104 between substation(s) and control center(s). It also gives guidelines for functions needed in a substation gateway device.

The goal of DD IEC/TS 61850-80-1 is to describe standardized mapping of device-oriented data models (for example IEC 61850) with already defined attributes of CDC's and services (for example IEC 61850-7) onto the already defined ASDU's and services of IEC 60870-5-104 or IEC 60870-5-101.

Contents of DD IEC/TS 61850-80-1:

FOREWORD

Scope and object

Normative references

Abbreviated terms

The mapping architecture

Conceptual architectures and associated use cases 

Conceptual architecture of a gateway device

Conceptual architecture of an IED directly connected to a WAN (optional)

Mapping of a device-oriented information model to IEC 60870-5-104 or IEC 60870-5-101

General

Mapping of a device-oriented information model reference

Logical device class mapping

Logical node class mapping

Mapping of the common data classes (CDC)

List of CDC, type Identifications and corresponding mappings for IEC 61850

CDC single point status (SPS)

CDC double point status (DPS)

CDC integer status (INS)

CDC protection activated information (ACT)

CDC directional protection activation information (ACD)

CDC Security violation counting (SEC)

CDC binary counter reading (BCR)

CDC measured value (MV)

CDC complex measured value (CMV

CDC Phase to ground related measured values of a three-phase system

(WYE)

CDC phase to phase measured values of a three phase system (DEL

CDC sequence (SEQ)

CDC harmonic value (HMV

CDC harmonic value for WYE (HWYE)

CDC harmonic value for DEL (HDEL)

CDC controllable single point (SPC)

CDC controllable double point (DPC)

CDC controllable integer status (INC)

CDC binary controlled step position information (BSC)

CDC integer-controlled step position information (ISC)

CDC controllable analogue set point information (APC)

CDC Single point setting (SPG)

CDC integer status setting (ING)

CDC analogue settings (ASG)

Mapping of services

List of service models and corresponding mappings

Server class mapping

Association class mapping

Logical node class mapping

Data class mapping

Setting group class mapping

Report control block class mapping

Control class mapping

Protocol stack selections for IEC 60870-5-101 and IEC 60870-5-104

General

Structure of application data

IEC 60870-5 interoperability