Air conditioners, liquid chilling packages and heat pumps with electrical driven compressors for space heating and cooling - Test methods

Air conditioners, liquid chilling packages and heat pumps with electrical driven compressors for space heating and cooling - Test methods

Regular price
£246.00
Sale price
£246.00
Regular price
£123.00
Sold out
Unit price
per 

BS EN 14511-3:2007 Air conditioners, liquid chilling packages and heat pumps with electrical driven compressors for space heating and cooling. Test methods

BS EN 14511-3 specifies the test methods for the rating and performance of various types of space heaters and coolers. Specifically, air and water-cooled air conditioners, liquid chilling packages, air-to-air, water-to-air, air-to-water and water-to-water heat pumps with electrically driven compressors are covered.

 

BS EN 14511-3 also specifies the method of testing and reporting for heat recovery capacities, system reduced capacities and the capacity of individual indoor units of multisplit systems, where applicable.

BS EN 14511-3 applies to:

• factory-made units that can be ducted

• factory-made liquid chilling packages with integral condensers or for use with remote condensers.

• factory-made units of either fixed capacity or variable capacity by any means

• packaged units, single split and multisplit systems

• single duct and double duct units

• air-to-air air conditioners which evaporate the condensate on the condenser side.

BS EN 14511-3 is primarily intended for water and brine chilling packages but can be used for other liquid subject to agreement.

BS EN 14511-3 does not apply to units using transcritical cycles, e.g. with CO2 as refrigerant. Installations used for heating and/or cooling of industrial processes are not within the scope of this standard. It does not apply to units that have their condensers cooled by air and by the evaporation of external additional water.

Contents of BS EN 14511-3

Foreword

Scope 

Normative references

Terms and definitions

Rating capacity test

Basic principles

Heating capacity

Cooling capacity 6

Heat recovery capacity

Power input of fans for units without duct connection

Power input of fans for units with duct connection

Power input of liquid pumps

Units for use with remote condenser

Test apparatus

Arrangement of the test apparatus

Installation and connection of the test object 

Uncertainties of measurement

Test procedure

General

Output measurement for water-to-water and water-to-air units

Output measurement for cooling capacity of air-to-water and air-to-air units

Output measurement for heating capacity of air-to-water and air-to-air units

Test results

Data to be recorded

Cooling capacity and heat recovery capacity calculation

Heating capacity calculation

Effective power input calculation

Heat recovery test for air-cooled multisplit systems

Test installation

General

Three-room calorimeter method

Three-room air-enthalpy method

Two-room air-enthalpy method

Test procedure

Test results

Test report

General information

Additional information

Rating test results

Calorimeter test method

Indoor air enthalpy test method

Heating capacity tests - Flow chart and examples of different test

sequences

Conformance criteria

Symbols used in annexes

Test at system reduced capacity

Individual unit tests

Bibliography